01Installation methods for ALS limit switches?
In general, the limit switches can be installed before or after the plates, both with screws.
-
02Action modes for limit switches?
According to the action modes of the heads of limit switches, it can be divided into three categories: plunger type (up and down), swinging arm type (left and right), universal type (action at any direction).
-
03Contact types for ALS1 switches?
Currently, we only have the contact type of 1NO 1NC with forced disconnection function.
-
04Mechanical action frequency of ALS1 limit switch?
The maximum operating frequency of ALS1-M is 7,200 times per hour; the maximum operating frequency of ALS-P is 6,000 times per hour; the mechanical operating frequency should not exceed 20 times per minute.
-
05Certifications that ALS series received?
CCC and CE.
-
06Do ALS series products meet the RoHS requirements?
Materials of ALS series products meet the requirements of EU RoHS standard.
-
07Head protection ratings for the ALS1-M and ALS1-P series?
IP65 and IP67, respectively.
-
08Rated insulation voltage for the ALS series limit switches?
AC440V
-
09Mechanical endurance of the ALS series limit switches?
Approximately 10 million times.
-
10Rated thermal current for the ALS series limit switches?
10A